← 返回 JSSC 论文列表JSSC 2013第10期Power Management0.35μm 2P4M CMOSBoost Converter
A Fast Fixed-Frequency Adaptive-On-Time Boost Converter With Light Load Ef ficiency Enhancement and Predictable
提出一种具有快速瞬态响应和增强轻载效率的固定频率自适应导通时间升压转换器
1.8V-3.2V输入电压,3.0V-4.2V输出电压,0mA-800mA负载电流范围,最大效率94.8%
自适应导通时间升压转换器频率锁定环轻载效率瞬态响应
▸采用频率锁定环自适应控制导通时间,使开关频率在全工作范围内跟踪参考频率误差小于0.5%
▸引入无毛刺导通时间控制电路提高频率锁定环的跟踪精度和速度
▸采用带数字滞回窗口的模式决策电路确保CCM和DCM模式间的平滑过渡
Abstract
An integrated fixed-frequency adaptive-on-time (AOT) DC-DC converter with fast transient response and enhanced high light-load ef ficiency is presented. At both Con- tinuous-Conduction-Mode (CCM) and Discontinuous-Conduc- tion-Mode (DCM) operation, the on-time is adaptively controlled by a frequency locked loop so that th e switching frequency tracks the reference frequency with less than 0.5% error in the whole operating range. At CCM operation, the reference frequency is fixed at 1 MHz. At light load with DCM operation, the reference frequency hops between 1 MHz and 1 MHz/N where and 1 to 5 according to the loads without load current sensor. Frequency hopping is introduced to boost the ef ficiency as well as reduce the EMI noise problem. A glitch-free on-time control circuit is introduced to increase the track accuracy and speed of the frequency locked loop. A mode decision circuit with digital hysteretic window is used to ensure a smooth transition between CCM and DCM operation. An on-time generator with proper logics is used to suppress frequency bouncing during frequenc y hopping. A prototype with 1.8 V–3.2 V input voltage, 3.0 V–4.2 V output voltage and 0 mA–800 mA load current range has been fabricated in a 0.35 m 2P4M CMOS process. Load transient measurements verify that 8 s–20 s recovery time is achieved for load current increase. Measurement results also show a maximum efficiency of 94.8% is achieved at total output power of 3.2 69 W, and the light load efficiency is enha