← 返回 JSSC 论文列表JSSC 2019第3期Power Management65nmBuck ConverterVCO
A Time-Domain-Controlled Current-Mode Buck Converter With Wide Output V oltage Range
采用时间域电路实现电流模式降压转换器,具有宽输出电压范围和高效能。
0.15-1.69V输出(1.8V输入), 0.6A最大负载, 94.9%峰值效率(1.5V/250mA), <3.5μs负载瞬态响应
时间域控制电流模式降压转换器宽输出电压高效能
▸使用VCO、VCDL和PD等时间域电路实现控制器,无需斜率补偿
▸通过VCO和VCDL组合实现II型频率补偿,省去误差放大器和RC网络
▸采用PD检测输出电压误差,实现宽范围开关占空比控制
Abstract
The controller of a current-mode buck converter is realized by only time-domain circuits such as voltage-controlled oscillator (VCO), voltage-controlled delay line (VCDL), and phase detector (PD). The inductor current is sensed by a VCO, which helps improving power efficiency and eliminates the need for the slope compensation preventing the sub-harmonic oscilla- tion. The type-II frequency compensation network is realized by a combination of VCO and VCDL without an error amplifier (EA) and RC network which may consume large power and occupy large silicon area. Instead of voltage comparator, a PD detects the error of the output voltage, which allows the switching duty cycle and thus the output voltage to be controlled in a wide range. With the proposed time-domain current-mode controller, a buck converter has been implemented in a 65-nm CMOS process. The output voltage can be regulated from 0.15 to 1.69 V from a 1.8-V input and the maximum load current is 0.6 A. The peak power efficiency is 94.9% when the output is 1.5 V and the load current is 250 mA. The load transient speed is better than 3.5 µs for both the step-up and step-down changes of the load current by 480 mA in 0.1 µs.