← 返回 JSSC 论文列表JSSC 2022第6期Power ManagementBoost Converter
A High Conversion Ratio and 97.4% High Efficiency Three-Switch Boost Converter With Duty-Dependent Charge Topology for 1.2-A High Driving Current and 20% Reduction of Inductor DC Current in MiniLED Applications Si-Yi Li, Student Member , IEEE, Y en-An Lin, Zheng-Lun Huang, Jia-Jyun Lee
提出一种三开关升压转换器,用于MiniLED面板,具有高转换比和高效率。
转换比=7.5, 驱动电流=1.2A, 效率=97.4%
三开关升压转换器MiniLED面板高转换比高效率RHP零点
▸采用三开关结构实现高转换比
▸通过动态调整RHP零点位置减少恢复时间
▸充电时间随占空比增加而增加
Abstract
This article presents a three-switch (3S) boost con- verter with hysteresis current control applied in MiniLED panels. It uses only three power switches to achieve high conversion ratio (=7.5) and low inductor current (20% lower than conventional boost converters). Meanwhile, the charging time of the flying capacitor will increase as the duty cycle increases. It enables the proposed 3S boost converter to have a high drive current (=1.2 A). In addition, the right half-plane (RHP) zero of the proposed topology is related to the switching frequency. By dynamically adjusting the position of RHP zero during transients, the recovery time and output voltage drop can be reduced at the same time. When the load increases from 120 mA to 1.2 A, the recovery time can be accelerated to 42 µs, and the maximum efficiency can reach 97.4%.