A 113.3-dB Dynamic Range 600 Frames/s SPAD X-Ray Detector With Seamless Global Shutter and Time-Encoded

一款具有1133dB动态范围和600帧无缝全局快门的SPAD X射线探测器
400 × 200像素阵列,49.5 µm像素间距,113.3 dB动态范围,127.2 mW功耗
SPADX射线探测器动态范围全局快门CMOS
创新点1:无缝全局快门操作(系统创新)。通过使用双计数器实现无缝全局快门操作,确保X射线光子100%的时间孔径,避免了传统快门操作中的时间损失,提升了检测效率。
创新点2:时间编码外推计数器(电路创新)。采用时间编码外推计数器,在低X射线剂量下实现全数字操作,避免读出噪声;在高剂量下通过外推模式扩展计数器深度,显著降低功耗并提升动态范围。
创新点3:高动态范围(HDR)设计(系统创新)。通过捕获计数器溢出时间(TOF)并利用积分时间(TINT)与TOF的比值扩展计数器深度,实现了113.3 dB的高动态范围,较之前提升了24.9 dB。
创新点4:φGCLK信号复用(电路创新)。通过复用计数器在TINT期间分发和累积φGCLK信号,简化了电路设计,仅需在像素阵列中分发φGCLK,降低了系统复杂度。
Abstract
This article presents a 400 × 200 single-photon avalanche diode (SPAD) X-ray detector that supports seamless global shutter operation. The pixel consists of an SPAD with two time-encoded extrapolation counters. For use under low X-ray dose conditions, the pixels and readout circuitry operate in a fully digital manner, avoiding the noise penalty of the readout. Under high X-ray dose conditions, the proposed counter operates in the extrapolation mode and thus achieves a high dynamic range (HDR), while reducing the counter’s power consump- tion. This is achieved by capturing the time of the counter overflow ( TOF) and expanding the counter depth by the ratio between the integration time ( TINT) and TOF. To reconstruct TOF, a φGCLK signal is distributed during TINT and accumulated from TOF to the end of TINT by reusing the counter. This only requires distribution of the φGCLK across the pixel array. Furthermore, seamless global shutter operation is realized through the use of two counters, which achieves a 100% temporal aperture for the X-ray photon. The proposed X-ray detector is implemented in a 1P5M 65-nm CMOS process. To be used for both medical diagnosis and industrial inspection, the pixel pitch is selected as 49.5 µm. The 400 × 200 detector achieves a dynamic range (DR) of 113.3 dB, while consuming only 127.2 mW. Compared with previous X-ray detectors, the proposed detector exhibits a 24.9-dB improvement in DR.