← 返回 JSSC 论文列表
📄 下载 JSSC 原文 PDF
JSSC 2025第11期Other110nm

A 46 µW 133-VPP Common-Mode Interference-Tolerant Biopotential Amplifier for Two-

一种针对两电极系统的生物电位放大器,能耐受130Vpp共模干扰并仅消耗46µW。
110nm CMOS, 1-1.5V供电, 4.6µW/通道, 130Vpp CMI耐受
生物电位放大器共模干扰抑制Miller效应电流复用OTA低功耗
利用Miller效应实现低共模输入阻抗的CMI-Follower
采用噪声高效的CMA-CR-OTA扩展输入共模范围
无需高功耗技术即可实现高共模抑制比
Abstract
This article presents a biopotential recording ana- log front-end (AFE) specifically tailored for a two-electrode measurement system, capable of capturing small biopotential signals while tolerating a large common-mode interference (CMI) over 130 V PP. By leveraging the Miller e ffect, the proposed CMI-Follower provides a significantly low common-mode input impedance ( ZIN-CM-C), achieving large CMI tolerance without additional noise contribution. The low ZIN-CM-C enables the isolated chip-ground (