A 110dB SNR ADC with ±30V Input Common-Mode Range and 8µV Offset for Current Sensing Applications

⚡ 本页包含 AI 生成的分析内容,仅供参考

📋 论文概要

本文提出一种用于电流检测的高压ΔΣ ADC,采用电容耦合高压斩波器实现±30V输入共模范围,结合相关双采样和系统级斩波将失调降至8µV,在5V单电源下达到110dB SNR,解决了传统ADC在高压电流监测中共模范围受限和精度不足的问题。

💡 主要创新点

核心指标
110dB SNR, ±30V input CMVR, 8µV offset
重要性
发表年份
ISSCC 2015

🏷 关键词

高压ADC电流检测高共模范围低失调ΔΣ调制器

📄 原文摘要

input common-mode voltage range (CMVR) while powered from a single 5V supply. This beyond-the-rails capability is obtained by employing a capacitively coupled high-voltage (HV) chopper at the input of a switched-capacitor (SC) ΔΣ ADC. Furthermore, the use of correlated double sampling and system-level chopping results in a maximum offset of 8μV over the full CMVR. In contrast to a recent HV ADC [1], the ADC exhibits 30dB more resolution, while its CMVR extends below the negative rail. The ADC is intended for current monitoring applications, in which a small voltage drop across a shunt resistor must be digitized. In battery monitoring applications, or when inductive loads are involved, the differential voltage across

👥 作者与机构

Long Xu1, Burak Gönen1, Qinwen Fan2, Johan H. Huijsing1, Kofi A. A. Makinwa1

Delft University of Technology, Delft, The Netherlands, Maxim Integrated Products, Delft, The Netherlands 1 2 This paper presents a high-resolution 110dB SNR ΔΣ ADC that achieves a ±30V

分类:Analog Circuits · 年份:ISSCC 2015