本文提出了一种10MHz时域控制的电流模式降压转换器,通过时域控制替代传统模拟电流环路,解决了电感电流传感器噪声敏感和次谐波振荡问题,实现了8.5%至93%的宽开关占空比。
Current-mode DC-DC converters offer various advantages over voltage-mode DCDC converters such as much simpler frequency compensation, automatic over-current protection, and faster transient response [1,2]. For current-mode control, however, an accurate inductor current sensor is required which can be very sensitive to noise. Another concern in designing a current-mode DC-DC converter is the instability under certain operating conditions known as subharmonic oscillation. A peak-current-mode buck converter, for example, may become unstable when its switching duty cycle is larger than 50% and slope compensation is required to ensure stable operation. While both current-mode and voltage-mode DC-DC converters are conventionally controlled by voltagedomain controllers that use voltage signals as control variables, the works in [3] and [4] have shown that voltage-mode DC-DC converters can also be controlled
Jin-Gyu Kang, Min-Gyu Jeong, Jeongpyo Park, Changsik Yoo
Hanyang University, Seoul, Korea