← 返回论文列表 📄 下载原文 PDF  ISSCC 2011 · 17.7
ISSCC 2011Session 17 · BIOMEDICAL & DISPLAYSMedical & Bio

A 160×128 Single-Photon Image Sensor with On-Pixel 55ps 10b Time-to-Digital Converter

⚡ 本页包含 AI 生成的分析内容,仅供参考

📋 论文概要

提出了一种160×128像素的单光子图像传感器,每个像素内集成了55ps分辨率、10位时间数字转换器(TDC),能够高精度地解析单个光子的到达时间,解决了荧光寿命成像(FLIM)等应用中对高时间分辨率光子检测的需求。

💡 主要创新点

核心指标
55ps时间分辨率, 10b TDC, 160×128像素
重要性
发表年份
ISSCC 2011

🏷 关键词

单光子图像传感器时间数字转换器荧光寿命成像SPAD

📄 原文摘要

Day-Uey Li3, Matthew W Fishburn1, Yuki Maruyama1, David Stoppa4, Fausto Borghetti4, Marek Gersbach5, Robert K Henderson3, Edoardo Charbon1 1 Delft University of Technology, Delft, The Netherlands, STMicroelectronics, Edinburgh, United Kingdom, 3 University of Edinburgh, Edinburgh, United Kingdom, 4 Fondazione Bruno Kessler - IRST, Trento, Italy, 5 EPFL, Lausanne, Switzerland 2 Image sensors capable of resolving the time-of-arrival (ToA) of individual photons with high resolution are needed in several applications, such as fluorescence lifetime imaging microscopy (FLIM), Förster resonance energy transfer (FRET), optical rangefinding, and positron emission tomography. In FRET, for example, typical fluorescence lifetime is of the order of 100 to 300ps, thus deepsubnanosecond resolutions are needed in the instrument response function (IRF). This in turn requires new time-resolved image sensors with better time

👥 作者与机构

Chockalingam Veerappan1, Justin Richardson2, Richard Walker2,3,

分类:Medical & Bio · 年份:ISSCC 2011