该论文提出了一种20位无时钟DAC,采用分段电压模式R-2R架构,实现了亚ppm线性度、7.5nV/√Hz低噪声和0.05ppm/°C低温漂,适用于医疗成像和科学仪器等对噪声和稳定性要求极高的应用。
Douglas Chisholm1, Denise T. Lee1 Analog Devices, Edinburgh, United Kingdom, Analog Devices, Wilmington, MA 1 2 DACs without continuous clocking are often favored in applications such as medical imaging and scientific instrumentation. The DACs in these high-precision systems are commonly endpoint-calibrated. After this calibration, a non-ideal DAC contributes three main sources of error: noise, temperature drift, and INL. The segmented voltage-mode R-2R DAC is an attractive architecture for reducing the first two of these error sources. Resistor Johnson noise is fixed by the DAC’s code-independent output resistance, which is readily lowered by the combination of several parallel segments. The complete signal path can be built using opamps that have a minimal noise gain of unity. This architecture also benefits from inherently zero endpoint error, avoiding any gain or offset drift over temperature.