← 返回论文列表 📄 下载原文 PDF  ISSCC 2019 · 10.1
ISSCC 2019Session 10 · SENSOR INTERFACESRF & Wireless

An Energy Measurement Front-End with Integrated In-Situ Background Full System Accuracy Monitoring Including the Current and Voltage Sensors

⚡ 本页包含 AI 生成的分析内容,仅供参考

📋 论文概要

本文提出一种能量测量前端,集成了原位背景全系统精度监测功能,能够在不中断测量的情况下持续监测电表的精度,解决了因元件老化和高压/电流事件导致的现场精度未知问题,避免了不必要的电表更换。

💡 主要创新点

重要性
发表年份
ISSCC 2019

🏷 关键词

能量测量前端背景精度监测状态监测电表

📄 原文摘要

to determine billable energy consumption. These devices are factory calibrated, and then perform measurement without interruption over their lifetime. Once in the field their accuracy is unknown due to component aging and high voltage/current events[1]. Meters are periodically replaced as a preventive measure, leading to the unnecessary replacement of perfectly good meters while some inaccurate meters may remain in field. This paper presents an energy-measurement front-end that enables continuous background Condition Base Monitoring (CbM) over the lifetime of a meter. Crucially it monitors the performance of its voltage and current sensors, which are typically the largest sources of inaccuracy and drift. During normal operation, small test signals (“stimuli”), with adaptable but well-defined

👥 作者与机构

Seyed Danesh1, William Holland1, Joe Spalding1, Michael Guidry2, J.E.D. Hurwitz1

Analog Devices, Edinburgh, United Kingdom; 2Analog Devices, Wilmington, MA 1 Millions of utility electricity meters are deployed globally

分类:RF & Wireless · 年份:ISSCC 2019