← 返回论文列表 📄 下载原文 PDF  ISSCC 2024 · 33.8
ISSCC 2024Session 33 · INTELLIGENT NEURAL INTERFACES AND SENSING SYSTEMSAI / ML

A Two-Electrode Bio-Impedance Readout IC with ComplexDomain Noise-Correlated Baseline Cancellation Supporting Sinusoidal Excitation

⚡ 本页包含 AI 生成的分析内容,仅供参考

📋 论文概要

该论文提出了一种采用复域噪声相关基线消除技术的两电极生物阻抗读出IC,解决了传统两电极配置中电极阻抗和电流发生器噪声引起的基线过大问题,支持正弦波激励。

💡 主要创新点

重要性
发表年份
ISSCC 2024

🏷 关键词

生物阻抗读出IC两电极配置基线消除复域噪声相关可穿戴监测

📄 原文摘要

As the demand for daily monitoring of physiological signals increases, the trend towards minimizing the size of devices through a two-electrode configuration has emerged as a new standard for wearable impedance monitoring. However, the two-electrode impedance measurement configuration suffers from its large baseline, further increased by the electrode impedance and the amplified noise of the current generator (CG). These challenges have been addressed by real-domain noise-correlated baseline cancellation (BC) techniques [1–3] (Fig. 33.8.1 (top)). It performs baseline subtraction using an IDAC, whose current is correlated with the current from the CG, at the front-end currentbalancing instrumentation amplifier (CBIA). This method operates well with square-wave

👥 作者与机构

Song-I Cheon*1, Haidam Choi*1, Gichan Yun1, Sein Oh1, Ji-Hoon Suh1,

Sohmyung Ha2, Minkyu Je1 Korea Advanced Institute of Science and Technology, Daejeon, Korea New York University Abu Dhabi, Abu Dhabi, United Arab Emirates *Equally Credited Authors (ECAs) 1 2

分类:AI / ML · 年份:ISSCC 2024