技术领域

Medical & Bio

211 篇相关论文 (2008–2026)

ISSCC 2018 Session 29 Medical & Bio
A 16384-Electrode 1024-Channel Multimodal CMOS MEA for High-Throughput Intracellular Action Potential Measurements and Impedance Spectroscopy in Drug-Screening Applications
Carolina Mora Lopez1, Ho Sung Chun1, Laurent Berti2, Shiwei Wang1,
Jan Putzeys1, Carl Van Den Bulcke1,3, Jan-Willem Weijers1, Andrea Firrincieli1, Veerle Reumers1, Dries Braeken1, Nick Van Helleputte1 imec, Heverlee, Belgium Chrysalite, Tervuren, Belgium 3 KU Leuven, Leuven, Belgium 1 2
ISSCC 2018 Session 29 Medical & Bio
A Fully Immersible Deep-Brain Neural Probe with Modular Architecture and a Delta-Sigma ADC Integrated Under Each Electrode for Parallel Readout of 144 Recording Sites
Daniel De Dorigo1, Christian Moranz1, Hagen Graf1, Maximilian Marx1,
tissue-penetrating probes for high-density deep-brain recording of in vivo neural activity is limited by the level of electronic integration on the probe shaft. As the number of electrodes increases, conventional devices
ISSCC 2018 Session 29 Medical & Bio
Creating Neural “Co-processors” to Explore Treatments for Neurological Disorders
Scott Stanslaski1, Jeffrey Herron1, Elizabeth Fehrmann1, Rob Corey1,
Heather Orser1, Enrico Opri3, Vaclav Kremen2, Ben Brinkmann2, Aysegul Gunduz3, Kelly Foote3, Greg Worrell2, Tim Denison1 Medtronic Neurological Technology, Fridley, MN Mayo Clinic, Rochester, MN 3 University of Florida,
ISSCC 2017 Session 27 Medical & Bio
Fully Integrated Optical Spectrometer with 500-to-830nm Range in 65nm CMOS
Lingyu Hong, Kaushik Sengupta
Next-generation IoT systems are expected to be enabled by compact, low-cost, low-power, smart sensing devices that provide a wealth of information to build new applications and capabilities. Among sensing modalities, opt
ISSCC 2017 Session 27 Medical & Bio
A 30.5mm3 Fully Packaged Implantable Device with Duplex Ultrasonic Data and Power Links Achieving 95kb/s with <10-4 BER at 8.5cm Depth
Ting Chia Chang, Max L. Wang, Jayant Charthad, Marcus J. Weber, Amin Arbabian
invasive miniaturized solutions that operate reliably at large depths, provide duplex communication for closed-loop therapies, and enable multi-access for a network of implants to gather information or provide systemic i
ISSCC 2017 Session 27 Medical & Bio
Single-Chip 3072ch 2D Array IC with RX Analog and All-Digital TX Beamformer for 3D Ultrasound Imaging
Yusaku Katsube1, Shinya Kajiyama2, Takuma Nishimoto1,
Tatsuo Nakagawa2, Yasuyuki Okuma3, Yohei Nakamura2, Takahide Terada2, Yutaka Igarashi1, Taizo Yamawaki2, Toru Yazaki1, Yoshihiro Hayashi2, Kazuhiro Amino2, Takuya Kaneko2, Hiroki Tanaka2 Hitachi, Yokohama, Japan Hitachi,
ISSCC 2017 Session 27 Medical & Bio
A Pixel-Pitch-Matched Ultrasound Receiver for 3D Photoacoustic Imaging with Integrated Delta-Sigma Beamformer in 28nm UTBB FDSOI
Man-Chia Chen1, Aldo Peña Perez1, Sri-Rajasekhar Kothapalli1,
in medical ultrasound rely on 3D volumetric imaging, calling for dense 2D transducer arrays with thousands of elements. Due to this high channel count, the traditional per-element cable interface used for 1D arrays is no
ISSCC 2017 Session 27 Medical & Bio
A Sub-1dB NF Dual-Channel On-Coil CMOS Receiver for Magnetic Resonance Imaging
Benjamin Sporrer1, Lianbo Wu1, Luca Bettini1, Christian Vogt1,
Jonas Reber2, Josip Marjanovic2, Thomas Burger1, David O. Brunner2, Klaas P. Prüssmann2, Gerhard Tröster1, Qiuting Huang1 ETH Zurich, Zurich, Switzerland University and ETH Zurich, Zurich, Switzerland 1 2 Magnetic Resona
ISSCC 2017 Session 27 Medical & Bio
All-Wireless 64-Channel 0.013mm2/ch Closed-Loop Neurostimulator with Rail-to-Rail DC Offset Removal
Hossein Kassiri1, M. Reza Pazhouhandeh2, Nima Soltani2,
M. Tariqus Salam3, Peter Carlen2,4, Jose Luiz Perez Velazquez2, Roman Genov2 York University, Toronto, Canada University of Toronto, Toronto, Canada 3 GSK (GlaxoSmithKline), Stevenage, United Kingdom 4 Toronto Western Ho
ISSCC 2017 Session 27 Medical & Bio
A 25.2mW EEG-NIRS Multimodal SoC for Accurate Anesthesia Depth Monitoring
Unsoo Ha1, Jaehyuk Lee1, Jihee Lee1, Kwantae Kim1, Minseo Kim1,
monitoring of the quantitative anesthesia (ANES) depth level for safe surgery [1]. However, the current ANES depth monitoring approach, bispectral index (BIS) [3], uses only EEG from the frontal lobe, and it shows critic
ISSCC 2017 Session 27 Medical & Bio
A 2.8µW 80mVpp-Linear-Input-Range 1.6GΩ-Input Impedance Bio-Signal Chopper Amplifier Tolerant to Common-Mode Interference up to 650mVpp
Hariprasad Chandrakumar, Dejan Marković
Closed-loop neuromodulation with simultaneous stimulation and sensing is desired to administer therapy in patients suffering from drug-resistant neurological ailments. However, stimulation generates large artifacts at th
ISSCC 2016 Session 28 Medical & Bio
CMOS Monolithic Airborne-Particulate-Matter Detector Based on 32 Capacitive Sensors with a Resolution of 65zF rms
Pietro Ciccarella, Marco Carminati, Marco Sampietro, Giorgio Ferrari
matter (PM) is well known [1]. Although optical and gravimetric instruments are available to detect PM, they lack portability, have poor potential for miniaturization, and are not low cost. Instead, a better spatio-tempo
ISSCC 2016 Session 28 Medical & Bio
A ±50mV Linear-Input-Range VCO-Based NeuralRecording Front-End with Digital Nonlinearity Correction
Wenlong Jiang1, Vahagn Hokhikyan1, Hariprasad Chandrakumar1,
tool for understanding the brain and driving the progress in neuroscience research and therapy. The local field potential (LFP) signals, which span from 3Hz to about 200Hz, serve as indicators of various neurological beh
ISSCC 2016 Session 28 Medical & Bio
A 0.6V 0.015mm2 Time-Based Biomedical Readout for Ambulatory Applications in 40nm CMOS
Rachit Mohan1,2, Samira Zaliasl3, Georges Gielen1,2,
applications in personal healthcare require sensor SoCs with low area, low power and a high dynamic range. Design in small-scale technologies can reduce the power and area of digital processing. However, due to the accom
ISSCC 2016 Session 28 Medical & Bio
A Battery-Powered Efficient Multi-Sensor
Acquisition System with Simultaneous ECG, BIO-Z, GSR, and PPG
Mario Konijnenburg1, Stefano Stanzione1, Long Yan2, Dong-Woo Jee2, Julia Pettine1, Roland van Wegberg1, Hyejung Kim2, Chris van Liempd1, Ram Fish3, James Schluessler3, Harmke de Groot1, Chris van Hoof1,2, Refet Firat Yaz
ISSCC 2016 Session 28 Medical & Bio
CMOS Biosensor IC Focusing on Dielectric Relaxations of Biological Water with 120GHz and 60GHz Oscillator Arrays
Takeshi Mitsunaka1, Nobuyuki Ashida1, Akira Saito1,
are reduced to 0.07GHz (resp. 0.03GHz) if we exclude the 52 elements (resp. 44 elements) on the periphery that exhibit larger deviations due to the anisotropy of the layout. A selected 120GHz (resp. 60GHz) element draws
ISSCC 2016 Session 28 Medical & Bio
A 14GHz Battery-Operated Point-of-Care ESR Spectrometer Based on a 0.13µm CMOS ASIC
Jonas Handwerker, Benedikt Schlecker, Ulrich Wachter,
spatial distribution, and even dynamics of paramagnetic species, electron spin resonance (ESR) spectroscopy is one of the most powerful analytical techniques in modern life sciences. Recently, the method has gained signi
ISSCC 2016 Session 28 Medical & Bio
A Handheld 50pM-Sensitivity Micro-NMR CMOS Platform with B-Field Stabilization for Multi-Type Biological/Chemical Assays
Ka-Meng Lei1, Hadi Heidari2,3, Pui-In Mak1, Man-Kay Law1,
Franco Maloberti2, Rui P. Martins1,4 University of Macau, Macau, China, University of Pavia, Pavia, Italy, 3 University of Glasgow, Glasgow, United Kingdom, 4 Instituto Superior Tecnico, Lisbon, Portugal 1 2 Point-of-use
ISSCC 2015 Session 21 Medical & Bio
A Wearable EEG-HEG-HRV Multimodal System with Real-Time tES Monitoring for Mental Health Management
Unsoo Ha, Yongsu Lee, Hyunki Kim, Taehwan Roh, Joonsung Bae,
based on EEG monitoring and transcranial electrical stimulation (tES)
ISSCC 2015 Session 21 Medical & Bio
A 16-ch Patient-Specific Seizure Onset and Termination Detection SoC with Machine-Learning and Voltage-Mode Transcranial Stimulation
Muhammad Awais Bin Altaf, Chen Zhang, Jerald Yoo
Multichannel EEG seizure detection SoCs are widely used in medical practice and in research [1]-[3]. Due to huge variation in seizure patterns, patient-specific seizure detection is very crucial. [1], [2] presents 8-chan
ISSCC 2015 Session 21 Medical & Bio
A 0.036mbar Circadian and Cardiac Intraocular Pressure Sensor for Smart Implantable Lens
Achille Donida1, Giuseppe Di Dato1, Paolo Cunzolo1, Marco Sala1,
worldwide acknowledged to be the main leading cause of irreversible blindness. High intraocular pressure (IOP) is considered the leading risk factor for glaucoma. Lowering IOP continues to be the only evidence-based trea
ISSCC 2015 Session 21 Medical & Bio
A Smart CMOS Assay SoC for Rapid Blood Screening Test of Risk Prediction
Po-Hung Kuo1, Jui-Chang Kuo1, Hsiao-Ting Hsueh1, Jian-Yu Hsieh1,
Taiwan University Hospital, Taipei, Taiwan 1 2 Rapid blood test is essential to disease control, risk assessment and point-ofcare testing. Conventional enzyme-linked immunosorbent assay (ELISA) requires several hours or
ISSCC 2015 Session 21 Medical & Bio
A Portable Micro Gas Chromatography System for Volatile Compounds Detection with 15ppb of Sensitivity
Te-Hsuen Tzeng, Chun-Yen Kuo, San-Yuan Wang, Po-Kai Huang,
Po-Hung Kuo, Yen-Ming Huang, Wei-Che Hsieh, Shih-An Yu, Yufeng Jane Tseng , Wei-Cheng Tian, Si-Chen Lee, Shey-Shi Lu National Taiwan Univeristy, Taipei, Taiwan Existing non-invasive lung cancer diagnostic equipment has d
ISSCC 2015 Session 21 Medical & Bio
A Microfluidic-CMOS Platform with 3D Capacitive Sensor and Fully Integrated Transceiver IC for Palmtop Dielectric Spectroscopy
Mehran Bakhshiani, Michael A. Suster, Pedram Mohseni
Quantitative measurement of the complex relative dielectric permittivity (εr) of a material vs. frequency (i.e., dielectric spectroscopy, or DS) is a powerful monitoring technique that extracts key information on molecul
ISSCC 2015 Session 21 Medical & Bio
A 6.45µW Self-Powered IoT SoC with Integrated Energy-Harvesting Power Management and ULP Asymmetric Radios
Alicia Klinefelter1, Nathan E. Roberts2, Yousef Shakhsheer1,
Patricia Gonzalez1, Aatmesh Shrivastava1, Abhishek Roy1, Kyle Craig1, Muhammad Faisal2, James Boley1, Seunghyun Oh2, Yanqing Zhang1, Divya Akella1, David D. Wentzloff2, Benton H. Calhoun1 University of Virginia, Charlott
ISSCC 2015 Session 21 Medical & Bio
A 3nW Signal-Acquisition IC Integrating an Amplifier with 2.1 NEF and a 1.5fJ/conv-step ADC
Pieter Harpe, Hao Gao, Rainier van Dommele, Eugenio Cantatore, Arthur van Roermund
unobtrusively wearable autonomous sensors, large sensor arrays, or wireless self-powered sensors, require a minuscule form factor and very low power consumption. For example, the power available from a state-of-the-art 1
ISSCC 2015 Session 21 Medical & Bio
A 79pJ/b 80Mb/s Full-Duplex Transceiver and a 42.5µW 100kb/s Super-Regenerative Transceiver for Body Channel Communication
Hyunwoo Cho, Hyunki Kim, Minseo Kim, Jaeeun Jang,
video streaming and image data to be shared with friends while wearable smart sensors continuously monitor and send user’s physiological information to a smart watch. Body channel communication (BCC), which uses the huma
ISSCC 2014 Session 24 Medical & Bio
An Analog-Digital-Hybrid Single-Chip RX Beamformer with Non-Uniform Sampling for 2D-CMUT Ultrasound Imaging to Achieve Wide Dynamic Range of Delay and Small Chip Area
Ji-Yong Um1, Eun-Woo Song1, Yoon-Jee Kim1, Seong-Eun Cho1,
Min-Kyun Chae1, Jongkeun Song2, Baehyung Kim2, Seunghun Lee2, Jihoon Bang2, Youngil Kim2, Kyungil Cho2, Byungsub Kim1, Jae-Yoon Sim1, Hong-June Park1 Pohang University of Science and Technology, Pohang, Korea, Samsung Ad
ISSCC 2014 Session 24 Medical & Bio
A 60nV/√Hz 15-Channel Digital Active Electrode System for Portable Biopotential Signal Acquisition
Jiawei Xu1,2, Benjamin Busze1, Hyejung Kim3, Kofi Makinwa2,
electrodes (AE), i.e., the combination of dry electrodes with in situ amplification, are increasingly used for biopotential measurements in emerging healthcare and lifestyle applications [1]. Compared to gel-based wet el
ISSCC 2014 Session 24 Medical & Bio
A CMOS Micro-Flow Cytometer for Magnetic Label Detection and Classification
Pramod Murali, Igor Izyumin, Daniel Cohen, Jun-Chau Chien,
Ali M. Niknejad, Bernhard Boser University of California, Berkeley, CA Flow cytometry is widely used in medicine for hematology, immunology, chemotherapy and pathology, as well as in food and water safety. While present
ISSCC 2014 Session 24 Medical & Bio
A 0.5V 1.27mW Nose-on-a-Chip for Rapid Diagnosis of Ventilator-Associated Pneumonia
Kea-Tiong Tang1, Shih-Wen Chiu1, Chung-Hung Shih2,
Chia-Ling Chang1, Chia-Min Yang1, Da-Jeng Yao1, Jen-Huo Wang1, Chien-Ming Huang1, Hsin Chen1, Kwuang-Han Chang1, Chih-Cheng Hsieh1, Ting-Hau Chang1, Meng-Fan Chang1, Chia-Min Wang1, Yi-Wen Liu1, Tsan-Jieh Chen3, Chia-Hsi
ISSCC 2014 Session 24 Medical & Bio
A 680nA Fully Integrated Implantable ECGAcquisition IC with Analog Feature Extraction
Long Yan1, Pieter Harpe2, Masato Osawa3, Yasunari Harada3,
Leuven, Belgium 1 2 Ultra-low power consumption and miniature size are by far the most important design requirements for implantable pacemakers. In order to guarantee a long life span of the device, saving power in the s
ISSCC 2014 Session 24 Medical & Bio
An Implantable 64nW ECG-Monitoring Mixed-Signal SoC for Arrhythmia Diagnosis
Dongsuk Jeon1, Yen-Po Chen1, Yoonmyung Lee1, Yejoong Kim1,
Zhiyoong Foo1, Grant Kruger1, Hakan Oral2, Omer Berenfeld2, Zhengya Zhang1, David Blaauw1, Dennis Sylvester1 University of Michigan, Ann Arbor, MI, University of Michigan Health System, Ann Arbor, MI 1 2 Electrocardiogra
ISSCC 2014 Session 24 Medical & Bio
A Power-Efficient Switched-Capacitor Stimulating System for Electrical/Optical Deep-Brain Stimulation
Hyung-Min Lee1, Ki-Yong Kwon2, Wen Li2, Maysam Ghovanloo1
Michigan State University, East Lansing, MI 1 2 Deep-brain stimulation (DBS) has been proven as an effective therapy to alleviate Parkinson’s disease, tremor, and dystonia. Towards a less invasive headmounted DBS, we uti
ISSCC 2014 Session 24 Medical & Bio
A Miniaturized 64-Channel 225µW Wireless Electrocorticographic Neural Sensor
Rikky Muller1,2, Hanh-Phuc Le1, Wen Li1, Peter Ledochowitsch1,
Simone Gambini2, Toni Bjorninen3, Aaron Koralek1, Jose M. Carmena1, Michel M. Maharbiz1, Elad Alon1, Jan M. Rabaey1 University of California, Berkeley, CA, University of Melbourne, Parkville, Australia, 3 Tampere Univers
ISSCC 2014 Session 18 Medical & Bio
A Remotely Controlled Locomotive IC Driven by Electrolytic Bubbles and Wireless Powering
Po-Hung Kuo1, Jian-Yu Hsieh1, Yi-Chun Huang1, Yu-Jie Huang1,
Taoyuan, Taiwan 1 As implantable medical CMOS devices become a reality [1], motion control of such implantable devices has become the next challenge in the advanced integrated micro-system domain. With integrated sensors
ISSCC 2014 Session 18 Medical & Bio
D Heterogeneously Integrated Bio-Sensing Microsystem for Multi-Channel Neural-Sensing Applications
Po-Tsang Huang1, Lei-Chun Chou1, Teng-Chieh Huang1, Shang-Lin Wu1,
Tang-Shuan Wang1, Yu-Rou Lin1, Chuan-An Cheng1, Wen-Wei Shen1, Kuan-Neng Chen1, Jin-Chern Chiou1,2, Ching-Te Chuang1, Wei Hwang1, Kuo-Hua Chen3, Chi-Tsung Chiu3, Ming-Hsiang Cheng3, Yueh-Lung Lin3, Ho-Ming Tong3 National
ISSCC 2014 Session 18 Medical & Bio
A 2.14mW EEG Neuro-Feedback Processor with Transcranial Electrical Stimulation for Mental-Health Management
Taehwan Roh, Kiseok Song, Hyunwoo Cho, Dongjoo Shin,
therapy based on Quantitative EEG (QEEG) and Event Related Potential (ERP) online data measurements. The U.S. Food and Drug Administration (FDA) approved the first EEG test for diagnosing attention deficit hyperactivity
ISSCC 2014 Session 18 Medical & Bio
A 4.9mΩ-Sensitivity Mobile Electrical Impedance Tomography IC for Early Breast-Cancer Detection System
Sunjoo Hong, Kwonjoon Lee, Unsoo Ha, Hyunki Kim,
S. women will develop breast cancer over the course of her lifetime, and breast cancer death rates are higher than those for any other cancer, besides lung cancer. In 2013, an estimated 232,340 new cases of invasive brea
ISSCC 2014 Session 18 Medical & Bio
A Multi-Parameter Signal-Acquisition SoC for Connected Personal Health Applications DC-offset isn’t cancelled after the input differential pair of the gm-stage the proposed method doesn’t face the power vs. noise vs. DC-offset range trade-off from CFBIAs with DC-servos.
Nick Van Helleputte1, Mario Konijnenburg2, Hyejung Kim1, Julia Pettine2,
Dong-Woo Jee1, Arjan Breeschoten2, Alonso Morgado1, Tom Torfs1, Harmke de Groot2, Chris Van Hoof1, Refet Firat Yazicioglu1 Various very low power signal processors have been demonstrated [2]. This is usually achieved thr
ISSCC 2014 Session 18 Medical & Bio
A Fully-Implantable Cochlear Implant SoC with Piezoelectric Middle-Ear Sensor and Energy-Efficient Stimulation in 0.18µm HVCMOS
Marcus Yip1, Rui Jin1, Hideko Heidi Nakajima2,3,
Konstantina M. Stankovic2,3, Anantha P. Chandrakasan1 Massachusetts Institute of Technology, Cambridge, MA, Harvard Medical School, Boston, MA, 3 Massachusetts Eye and Ear Infirmary, Boston, MA 1 2 A cochlear implant (CI
ISSCC 2014 Session 18 Medical & Bio
A 1V 3mA 2.4GHz Wireless Digital Audio Communication SoC for Hearing-Aid Applications in 0.18μm CMOS
Amre El-Hoiydi1, François Callias1, Yves Oesch1,
Hearing aids are complex integrated and highly miniaturised systems based on digital signal processor and wireless communication chips. There is a growing need for wireless connectivity between hearing aids and external
ISSCC 2013 Session 6 Medical & Bio
Experimental Demonstration of a Fully Digital Capacitive Sensor Interface Built Entirely Using Carbon-Nanotube FETs
Max Shulaker1, Jelle Van Rethy2, Gage Hills1, Hong-Yu Chen1,
Georges Gielen2, H.-S. Philip Wong1, Subhasish Mitra1 Stanford University, Stanford, CA, KU Leuven, Heverlee, Belgium 1 2 Low-power applications, such as sensing, are becoming increasingly important and demanding in term
ISSCC 2013 Session 6 Medical & Bio
A 1024×8 700ps Time-Gated SPAD Line Sensor for Laser Raman Spectroscopy and LIBS in Space and Rover-Based Planetary Exploration
Yuki Maruyama1, Jordana Blacksberg2, Edoardo Charbon1
Jet Propulsion Laboratory, Pasadena, CA 1 2 Raman spectroscopy is a nondestructive, label-free optical analysis technique used to obtain structural and compositional information without any advance preparation. However,
ISSCC 2013 Session 6 Medical & Bio
An Organic VCO-Based ADC for Quasi-Static Signals Achieving 1LSB INL at 6b Resolution
Daniele Raiteri1, Pieter van Lieshout2, Arthur van Roermund1, Eugenio Cantatore1
read out using RFID protocols, are an important future application of large-area organic electronics. The first steps towards flexible organic electronics were code generators for RFID tags [1]. To realize flexible smart
ISSCC 2013 Session 6 Medical & Bio
A 4b ADC Manufactured in a Fully-Printed Organic Complementary Technology Including Resistors
Sahel Abdinia1, Mohamed Benwadih2, Romain Coppard2,
of Technology, Eindhoven, The Netherlands, CEA-LITEN, Grenoble, France, 3 University of Catania, Catania, Italy, 4 STMicroelectronics, Catania, Italy 1 2 Organic transistors (OTFTs) can be printed on thin plastic substra
ISSCC 2013 Session 6 Medical & Bio
1µm-Thickness 64-Channel Surface Electromyogram Measurement Sheet with 2V Organic Transistors for Prosthetic Hand Control
Hiroshi Fuketa1,2, Kazuaki Yoshioka1,2, Yasuhiro Shinozuka1,2,
Koichi Ishida1,2, Tomoyuki Yokota1,2, Naoji Matsuhisa1,2, Yusuke Inoue1,2, Masaki Sekino1,2, Tsuyoshi Sekitani1,2, Makoto Takamiya1,2, Takao Someya1,2, Takayasu Sakurai1,2 University of Tokyo, Tokyo, Japan, 2JST/ERATO, T
ISSCC 2013 Session 6 Medical & Bio
Through-Silicon-Via-Based Double-Side Integrated Microsystem for Neural Sensing Applications
Chih-Wei Chang1, Po-Tsang Huang1, Lei-Chun Chou1, Shang-Lin Wu1,
Shih-Wei Lee1, Ching-Te Chuang1, Kuan-Neng Chen1, Jin-Chern Chiou1,2, Wei Hwang1,3, Yen-Chi Lee3, Chung-Hsi Wu3, Kuo-Hua Chen3, Chi-Tsung Chiu3, Ho-Ming Tong3 National Chiao Tung University, Hsinchu, Taiwan, 2 China Medi
ISSCC 2013 Session 6 Medical & Bio
A 1.83µJ/Classification Nonlinear Support-VectorMachine-Based Patient-Specific Seizure Classification SoC
Muhammad Awais Bin Altaf, Judyta Tillak, Yonatan Kifle, Jerald Yoo
To mitigate seizure-affected patients, SoCs [1-3] have been developed 1) to detect electrical onset of seizure seconds before the clinical onset, and 2) to combine the SoC with neurostimulation. In particular, having det
ISSCC 2013 Session 6 Medical & Bio
An 87mA·min Iontophoresis Controller IC with DualMode Impedance Sensor for Patch-Type Transdermal Drug Delivery System
Kiseok Song, Unsoo Ha, Jaehyuk Lee, Kyeongryeol Bong, Hoi-Jun Yoo
Iontophoresis enhances drug penetration non-invasively into body tissue by electrical stimulation [1]. Compared with injection and oral dosage, it has advantages in the ease of use, the minimization of side effects, such